Catalogue number | Number of fibers | Diameter (mm) | Weight (kg/km) |
A-W(ZN-2P)2Y-1E-1,5kN | 1 | 5.0 | 21.7 |
A-D(ZN-2P)2Y-2E-1,5kN | 2 | 5.0 | 21.7 |
A-D(ZN-2P)2Y-4E-1,5kN | 4 | 5.0 | 21.7 |
A-D(ZN-2P)2Y-8E-1,5kN | 8 | 6.0 | 30.3 |
A-D(ZN-2P)2Y-12E-1,5kN | 12 | 6.0 | 30.5 |
A-D(ZN-2P)2Y-16E-1,5kN | 16 | 6.4 | 34.3 |
A-D(ZN-2P)2Y-24E-1,5kN | 24 | 6.4 | 34.6 |
Fiber:
- Single Mode fiber G.652 D
- 1÷24 fibers
- Central tube gel-filled
- Color coding per IEC 60304 – DIN VDE0888
Outer Jacket:
- Black UV* resistant polyethylene (PE)
- Sequential meter marking
Features:
- Central tube armored two FRP E.A.A coated rods
- Resistant to tension loads and shell stretching
Mechanical characteristics:
- Max distance between poles – 90 m**
- Max sagging – 2%
- Cable weight – see table
- Cable diameter – see table
- Cable length – 2 to 4 km/reel

Performance:
- Temperature
Installation -20°C to +50°C (-4°F to +122°F)
Operating -40°C to +60°C (-40°F to +140°F)
- Minimum band radius
15 nominal diameters of cable
- Maximum crash resistance
200 N/cm (17,7 lb/in)
- Maximum tension load
1500 H
*UV – ultraviolet
**This length is indicated for regions with a minimum wind exposure and icing