Optic cable А-DQ(ZN-GYSR)2Y xTyЕ 1,5kN

Construction number: G15PxM
label

For laying on roofs, facades, poles and other open areas where there is significant exposure to ultraviolet radiation.

UV resistant

label

For direct installation in the ground, for external installation in trenches or using ground drilling rigs.

Direct burying

label

For laying in cable ducts or collectors. Also used for pulling into pipes.

Cable duct

label

For laying in soil, sewers, technical rooms and rural areas where rodents are found.

Rodent protection

label

For laying outdoors – on facades, poles, in the ground, outdoors.

Outdoor

А-DQ(ZN-GYSR)2Y xTyЕ 1,5kN is a multitube design of armored optical cable designed for laying in soils of 1-3 categories, in cable ducts and conduits. It is intended for use in distribution and trunk networks, for connecting apartment buildings, industrial and office buildings, and supports fiber counts from 6 to 144. The cable has a central FRP rod and a peripheral layer of glass roving as strength elements that provide resistance to stretching and deformation during installation. Rodent protection is provided by laminated corrugated steel tape, which also increases the overall strength of the cable in aggressive environments. Moisture protection is provided by a gel inside the tubes and a water-blocking tape between the tubes. Optionally, a special gel can be between the tubes to protect against moisture. The cable can withstand short-term tensile loads of up to 1.5 kN. The outer sheath is made of UV-stabilized HDPE

Cable construction

  1. Central strength member: FRP rod
  2. FRP jacketing: Polyethylene (HDPE)
  3. Optical fiber: Single-mode Rec. ITU-T G.652.D
  4. Filler: Thixotropic filling compound (gel)
  5. Loose Tube: Polybutylene terephthalate (PBT)
  6. Dummy filler: Polyethylene (HDPE)
  7. Peripheral strength member: Water blocking glass yarn
  8. Water blocking element: Water blocking yarn
  9. Protective metal element: Steel tape
  10. Outer jacket: Polyethylene (HDPE), black, UV-resistance

Advanced features

The table scrolls sideways

Cable ID G15P6M G15P8M G15P9M G15PBM G15PGM G15PHM G15PEM G15PKM G15PNM G15PRM G15PTM G15PXM
Number of optical fibers 8 12 16 24 36 48 72 96 144
Construction 2х4 2х6 3х4 4х4 4х6 6х4 2х12 3х12 4х12 6х12 8х12 12х12
Optical fiber

info

Default Fiber Standard

Learn More

Single-mode Rec. ITU-T G.652.D
Cladding Diameter (±0,7), µm 125
Cladding Diameter (±5), µm 242
Attenuation (λ= 1310 nm), dB/кm ≤ 0,32
Attenuation (λ= 1550 nm), dB/кm ≤ 0,22
Number of elements 6 8 12
Number of fillers 4 3 2 0 4 3 2 0
Cable diameter (±0,6), mm 9,2 10,4 12
Cable weight (±5%), kg/km 85 86 87 86 87 89 106 138
Max. Tension Installation , kN 1,5 1,8 2
Max. Tension Operational, kN 0,4 0,5 0,6
Crush resistance, N/10 cm 3000
Temperature operation, °C -40 … +60
Temperature installation, °C -10 … +50
Temperature storage, °C -40 … +60
Min. bending radius 20 Ø cable
Color coding
info

Default fiber color sequence

More details

1RD
2GN
3BU
4YE
5WH
6GY
7BN
8VT
9TQ
10BK
11OG
12PK

Do you have any questions?