Optical cable Micro А-DQ(ZN)2Y xTyЕ 1.0kN (t1.5)

Construction number: B10PxS1
label

For laying on roofs, facades, poles and other open areas where there is significant exposure to ultraviolet radiation.

UV resistant

label

Safe for installation near power lines, lightning protection and high-voltage equipment.

All-dielectric

label

For laying by pneumatic blowing into microducts or cable ducts.

Blowing installation

label

For laying outdoors – on facades, poles, in the ground, outdoors.

Outdoor

Micro А-DQ(ZN)2Y xTyЕ is a micro-tubes optical cable designed for installing communication networks using the technology of blowing into tubes. It is suitable for building modern fibre-optic networks with high fiber density, including FTTx solutions and intra-quarter distributions. The design is based on thin 1.5 mm diameter micromodules, which significantly reduces the outer diameter of the cable while maintaining high fiber density - up to 144 fibers. The central strength element is a glass rod, which ensures the stability of the cable during installation and pulling.

Cable construction

  1. Optical fiber: Single-mode Rec. ITU-T G.652.D
  2. Filler: Thixotropic filling compound (gel)
  3. Dummy filler:  Polyethylene (HDPE)
  4. Loose Tube: Polybutylene terephthalate (PBT)
  5. Central strength member: FRP rod
  6. FRP jacketing: Polyethylene (HDPE)
  7. Water blocking element: Water blocking yarn
  8. Fixing element: Aramid yarn
  9. Ripcord: Polyester yarn
  10. Outer jacket: Polyethylene (HDPE), black, UV-resistance

Advanced features

The table scrolls sideways

Cable ID B10P7S1 B10P8S1 B10PGS1 B10PES1 B10PKS1 B10PNS1 B10PRS1 B10PTS1 B10PXS1
Optical fiber 12 12 24 24 36 48 72 96 144
Construction 1х12 2х6 4×6 2х12 3х12 4х12 6х12 8х12 12х12
Optical fiber

info

Default Fiber Standard

Learn More

Single-mode Rec. ITU-T G.652.D
Cladding Diameter (±0,7), µm 125
Coating Diameter (±5), µm 242
Attenuation (λ= 1310 nm), dB/кm ≤ 0,32
Attenuation (λ= 1550 nm), dB/кm ≤ 0,22
Number of elements 6 8 12
Loose Tube diameter (±0,2), mm 1,5
Number of fillers 5 4 2 4 3 2 0
Cable diameter (±0,4), mm 5,6 6,6 8,4
Cable weight (±5%), kg/km 24 25 26 27 38 59
Max. Tension Installation , kN 0,7 1,0 1,2 1,5
Crush resistance, N/10 cm 500
Temperature operation, °C -40 … +60
Temperature installation, °C -10 … +50
Temperature storage, °C -40 … +60
Min. bending radius 20 Ø cable
Color coding
info

Default fiber color sequence

More details

1RD
2GN
3BU
4YE
5WH
6GY
7BN
8VT
9TQ
10BK
11OG
12PK