Optical cable А-D(ZN-2P)2Y xЕ 2,0kN

Construction number: A20TxC
label

For laying on roofs, facades, poles and other open areas where there is significant exposure to ultraviolet radiation.

UV resistant

label

Safe for installation near power lines, lightning protection and high-voltage equipment.

All-dielectric

label

For laying outdoors – on facades, poles, in the ground, outdoors.

Outdoor

label

For air laying on supports or between buildings.

Aerial

А-D(ZN-2P)2Y xЕ 2,0kN is a self-supporting dielectric optical cable of ADSS type designed for suspension in distribution networks, on sections of fiber-optic lines with increased distance between poles. It is optimally suited for installation on power line poles in spans of up to 130 m (depending on climatic conditions). The design includes two FRP rods with EAA coating, which ensures reliable fixation in cable clamps and reduces the risk of damage to the sheath under operating loads. The cable can withstand short-term tensile forces of up to 2 kN. The available EFL prevents fiber retraction in suspension conditions. The sheath is made of high-density polyethylene (HDPE), which provides resistance to UV radiation, moisture and mechanical stress.

Cable construction

  1. Optical fiber: Single-mode Rec. ITU-T G.652.D
  2. Peripheral strength member: FRP rod
  3. Filler: Thixotropic filling compound (gel)
  4. Loose Tube: Polybutylene terephthalate (PBT)
  5. Outer jacket: Polyethylene (HDPE), black, UV-resistance

Advanced features

The table scrolls sideways

Cable ID A20T1C A20T2C A20T3C A20T5C A20T7C A20TEC
Number of optical fibers 1 2 4 8 12 24
Optical fiber

info

Default Fiber Standard

Learn More

Single-mode Rec. ITU-T G.652.D
Cladding Diameter (±0,7), µm 125
Cladding Diameter (±5), µm 242
Attenuation (λ= 1310 nm), dB/кm ≤ 0,32
Attenuation (λ= 1550 nm), dB/кm ≤ 0,22
Diameter of the central tube (±0,2), mm 1,8 2,5 3,0
Cable diameter (±0,4), mm 5,8 6,5 7,0
Cable weight (±5%), kg/km 30,0 37,0 43,0
Max. Tension Installation , kN 2,0
Max. Tension Operational, kN 1,0
Crush resistance, N/10 cm 3000
Temperature operation, °C -40 … +70
Temperature installation, °C -10 … +50
Temperature storage, °C -40 … +70
Min. bending radius 15 Ø cable
Color coding
info

Default fiber color sequence

More details

1RD
2GN
3BU
4YE
5WH
6GY
7BN
8VT
9TQ
10BK
11OG
12PK

Calculate the cable according to your conditions

Or, you can call us right away.

1
2
This field is required.

Select climate conditions by NESC

info

Multifunctional cables for both indoor and outdoor installation. One cable, many solutions.

Розрахувати кабель відповідно до ваших умов

Do you have any questions?

Fill out the form and we will contact you shortly to clarify all issues.