Optical cable А-DQ(ZM-SR)2Y xE 2,7kN

Construction number: G27TxQ
label

For laying on roofs, facades, poles and other open areas where there is significant exposure to ultraviolet radiation.

UV resistant

label

For direct installation in the ground, for external installation in trenches or using ground drilling rigs.

Direct burying

label

For laying in cable ducts or collectors. Also used for pulling into pipes.

Cable duct

label

For laying in soil, sewers, technical rooms and rural areas where rodents are found.

Rodent protection

label

For laying outdoors – on facades, poles, in the ground, outdoors.

Outdoor

А-DQ(ZM-SR)2Y xE 2,7kN is an armored optical cable with a central optical tube designed for outdoor installation in cable sewers, pipelines, cable ducts and soils of categories 1-3. It is suitable for distribution networks and FTTB applications with support for fiber counts from 2 to 24. The construction includes a laminated corrugated metal tape for effective protection against rodents and compression. The strength elements are metal rods with a diameter of 1.2 mm, which provide short-term load capacity of up to 2.7 kN. The central optical tube with a thixotropic gel prevents moisture to the fibers, and the space between the tube and the reinforced tape is additionally protected by a water-blocking tape. The outer jacket is made of UV-stabilized high-density polyethylene (HDPE), resistant to external influences in difficult conditions.

Cable construction

  1. Optical fiber: Single-mode Rec. ITU-T G.652.D
  2. Loose Tube: Polybutylene terephthalate (PBT)
  3. Filler: Thixotropic filling material (gel)
  4. Water blocking element: Water blocking yarn
  5. Protective metal element: Steel tape
  6. Peripheral strength member: Steel wire
  7. Protection jacket: Polyethylene (HDPE), black

Advanced features

The table scrolls sideways

Cable ID G27T1Q G27T2Q G27T3Q G27T5Q G27T7Q G27TAQ G27TEQ
Number of optical fibers 1 2 4 8 12 16 24
Optical fiber

info

Default Fiber Standard

Learn More

Single-mode Rec. ITU-T G.652.D
Cladding Diameter (±0,7), µm 125
Cladding Diameter (±5), µm 242
Attenuation (λ= 1310 nm), dB/кm ≤ 0,32
Attenuation (λ= 1550 nm), dB/кm ≤ 0,22
Central tube diameter (±0,2), mm 2,5
Cable diameter (±0,5), mm 8,2
Cable weight (±5%), kg/km 79 80
Max. Tension Installation , kN 2,7
Max. Tension Operational, kN 1,5
Crush resistance, N/10 cm 3000
Temperature operation, °C -40 … +70
Temperature installation, °C -10 … +50
Temperature storage, °C -40 … +70
Min. bending radius 20 Ø cable
Color coding
info

Default fiber color sequence

More details

1RD
2GN
3BU
4YE
5WH
6GY
7BN
8VT
9TQ
10BK
11OG
12PK